Add short within trace interleaved batch

This commit is contained in:
jaseg 2025-07-11 19:45:34 +02:00
parent bfb5a2c74e
commit 7642a0e3ee
14 changed files with 412 additions and 283 deletions

File diff suppressed because one or more lines are too long

Binary file not shown.

Binary file not shown.

Binary file not shown.

Binary file not shown.

View file

@ -1,4 +1,4 @@
Results calculated from plots fig_covar_hot_mesh.pdf / fig_cdf_hot_mesh.pdf on 2025-07-10T11:36:26.942829
Results calculated from plots fig_covar_hot_mesh.pdf / fig_cdf_hot_mesh.pdf on 2025-07-11T17:01:24.372970
setting threshold for quantile 0.001
Baseline threshold set at 0.980069

View file

@ -1,4 +1,4 @@
Results calculated from plots fig_covar_patch_interleave_baseline.pdf / fig_cdf_patch_interleave_baseline.pdf on 2025-07-11T16:56:05.011425
Results calculated from plots fig_covar_patch_interleave_baseline.pdf / fig_cdf_patch_interleave_baseline.pdf on 2025-07-11T19:17:04.741667
setting threshold for quantile 0.001
Baseline threshold set at 0.985280

View file

@ -1,4 +1,4 @@
Results calculated from plots fig_covar_patch_ref_exp_interleave_direct.pdf / <none> on 2025-07-11T16:56:52.209622
Results calculated from plots fig_covar_patch_ref_exp_interleave_direct.pdf / <none> on 2025-07-11T19:17:12.277084
setting threshold for quantile 0.001
Baseline threshold set at 0.979357

View file

@ -1,4 +1,4 @@
Results calculated from plots fig_covar_touch_combined.pdf / fig_cdf_touch_combined.pdf on 2025-07-10T17:05:18.731896
Results calculated from plots fig_covar_touch_combined.pdf / fig_cdf_touch_combined.pdf on 2025-07-11T17:06:11.411547
setting threshold for quantile 0.001
Baseline threshold set at 0.978979

View file

@ -1154,7 +1154,7 @@ a patching attack from a \emph{skilled} attacker to an \emph{expert} attacker, a
\begin{subfigure}[t]{0.23\textwidth}
\includegraphics[width=\textwidth]{fig_covar_probe_points_p0.3.pdf}
\label{}
\caption{Baseline vs. for previous plots specimens with soldermask removed}
\caption{Baseline vs. specimens with soldermask removed for previous plots}
\end{subfigure}
\caption{}
%too much: fig_covar_soldering_p0.3_minmax.pdf
@ -1183,6 +1183,14 @@ a patching attack from a \emph{skilled} attacker to an \emph{expert} attacker, a
\label{}
\end{figure}
\begin{figure}[H]
\centering
\includegraphics[width=1.0\textwidth]{fig_tempco_edited.pdf}
\caption{The effect of heating on a time-domain trace. One of 12 channels shown. Gray: Raw data. Black: Relative
difference between hot and cool cases.}
\label{fig_pic_board}
\end{figure}
\begin{figure}[H]
\begin{subfigure}[t]{0.27\textwidth}
\includegraphics[width=\textwidth]{fig_covar_patch_interleave_baseline.pdf}
@ -1212,51 +1220,47 @@ a patching attack from a \emph{skilled} attacker to an \emph{expert} attacker, a
\begin{subfigure}[t]{0.23\textwidth}
\includegraphics[width=\textwidth]{fig_covar_open_p0.3.pdf}
\label{}
\caption{}
\caption{Open, p=\qty{0.3}{\milli\meter}}
\end{subfigure}
\hfill
\begin{subfigure}[t]{0.23\textwidth}
\includegraphics[width=\textwidth]{fig_covar_short_across_traces_p0.3.pdf}
\label{}
\caption{}
\caption{Short, p=\qty{0.3}{\milli\meter}}
\end{subfigure}
\hfill
\begin{subfigure}[t]{0.23\textwidth}
\includegraphics[width=\textwidth]{fig_covar_open_p0.4.pdf}
\label{}
\caption{}
\caption{Open, p=\qty{0.4}{\milli\meter}}
\end{subfigure}
\hfill
\begin{subfigure}[t]{0.23\textwidth}
\includegraphics[width=\textwidth]{fig_covar_short_across_traces_p0.4.pdf}
\label{}
\caption{}
\caption{Short, p=\qty{0.4}{\milli\meter}}
\end{subfigure}
\caption{}
\label{}
\end{figure}
\begin{figure}[H]
\begin{subfigure}[t]{0.48\textwidth}
\includegraphics[width=\textwidth]{fig_covar_distinguish_layouts.pdf}
\label{}
\caption{Different mesh layouts, Missed alarm rate 18\% at 0.1\% false alarm rate, CER=0\%}
\end{subfigure}
\hfill
\begin{subfigure}[t]{0.48\textwidth}
\includegraphics[width=\textwidth]{fig_covar_distinguish_copies_large_run.pdf}
\label{}
\caption{Three identical copies, Missed alarm rate 1.7\% at 0.1\% false alarm rate, CER=0\%}
\end{subfigure}
\caption{}
\caption{Covariance matrix of intact (top left) and modified meshes (bottom right). Shown are two pitches. Ten
specimens each with either one trace interrupted, or both traces shorted in a random location.}
\label{}
\end{figure}
\begin{figure}[H]
\centering
\includegraphics[width=1.0\textwidth]{fig_tempco_edited.pdf}
\begin{subfigure}[t]{0.28\textwidth}
\includegraphics[width=\textwidth]{fig_covar_distinguish_layouts.pdf}
\label{}
\caption{Different mesh layouts, False negative rate 18\% at 0.1\% false positive rate, CER=0\%}
\end{subfigure}
\hspace*{5mm}
\begin{subfigure}[t]{0.28\textwidth}
\includegraphics[width=\textwidth]{fig_covar_distinguish_copies_large_run.pdf}
\label{}
\caption{Three identical copies, False negative rate 1.7\% at 0.1\% false positive rate, CER=0\%}
\end{subfigure}
\hfill
\caption{}
\label{fig_pic_board}
\label{}
\end{figure}
\end{tcolorbox}