1112 lines
80 KiB
TeX
1112 lines
80 KiB
TeX
\documentclass[12pt,a4paper,notitlepage]{report}
|
|
\usepackage[utf8]{inputenc}
|
|
\usepackage[a4paper,textwidth=17cm, top=2cm, bottom=3.5cm]{geometry}
|
|
\usepackage[T1]{fontenc}
|
|
\usepackage[
|
|
backend=biber,
|
|
style=numeric,
|
|
natbib=true,
|
|
url=true,
|
|
doi=true,
|
|
eprint=false
|
|
]{biblatex}
|
|
\addbibresource{safety_reset.bib}
|
|
\usepackage{amssymb,amsmath}
|
|
\usepackage{listings}
|
|
\usepackage{eurosym}
|
|
\usepackage{wasysym}
|
|
\usepackage{amsthm}
|
|
\usepackage{tabularx}
|
|
\usepackage{multirow}
|
|
\usepackage{multicol}
|
|
\usepackage{tikz}
|
|
\usepackage{mathtools}
|
|
\DeclarePairedDelimiter{\ceil}{\lceil}{\rceil}
|
|
\DeclarePairedDelimiter{\paren}{(}{)}
|
|
|
|
\usetikzlibrary{arrows}
|
|
\usetikzlibrary{chains}
|
|
\usetikzlibrary{backgrounds}
|
|
\usetikzlibrary{calc}
|
|
\usetikzlibrary{decorations.markings}
|
|
\usetikzlibrary{decorations.pathreplacing}
|
|
\usetikzlibrary{fit}
|
|
\usetikzlibrary{patterns}
|
|
\usetikzlibrary{positioning}
|
|
\usetikzlibrary{shapes}
|
|
|
|
\usepackage{hyperref}
|
|
\usepackage{tabularx}
|
|
\usepackage{commath}
|
|
\usepackage{graphicx,color}
|
|
\usepackage{subcaption}
|
|
\usepackage{float}
|
|
\usepackage{footmisc}
|
|
\usepackage{array}
|
|
\usepackage[underline=false]{pgf-umlsd}
|
|
\usetikzlibrary{calc}
|
|
%\usepackage[pdftex]{graphicx,color}
|
|
\usepackage{epstopdf}
|
|
\usepackage{pdfpages}
|
|
% Needed for murks.tex
|
|
\usepackage{setspace}
|
|
\usepackage[draft=false,babel,tracking=true,kerning=true,spacing=true]{microtype} % optischer Randausgleich etc.
|
|
% For german quotation marks
|
|
|
|
\newcommand{\foonote}[1]{\footnote{#1}}
|
|
\newcommand{\degree}{\ensuremath{^\circ}}
|
|
\newcolumntype{P}[1]{>{\centering\arraybackslash}p{#1}}
|
|
|
|
\usepackage{fancyhdr}
|
|
\fancyhf{}
|
|
\fancyfoot[C]{\thepage}
|
|
|
|
\begin{document}
|
|
|
|
% Beispielhafte Nutzung der Vorlage für die Titelseite (bitte anpassen):
|
|
\input{murks}
|
|
\titelen{A Post-Attack Recovery Architecture for Smart Electricity Meters}
|
|
\titelde{Eine Architektur zur Kontrollwiederherstellung nach Angriffen auf Smart Metering in Stromnetzen}
|
|
\typ{Masterarbeit}
|
|
\grad{Master of Science (M. Sc.)}
|
|
\autor{Jan Sebastian Götte}
|
|
\gebdatum{Aus Datenschutzgründen nicht abgedruckt} % Geburtsdatum des Autors
|
|
\gebort{Aus Datenschutzgründen nicht abgedruckt} % Geburtsort des Autors
|
|
\gutachter{Prof. Dr. Björn Scheuermann}{Prof. Dr.-Ing. Eckhard Grass}
|
|
\mitverteidigung % entfernen, falls keine Verteidigung erfolgt %FIXME
|
|
\makeTitel
|
|
\selbstaendigkeitserklaerung{31.03.2020}
|
|
\newpage
|
|
|
|
% Hier folgt die eigentliche Arbeit (bei doppelseitigem Druck auf einem neuen Blatt):
|
|
\tableofcontents
|
|
\newpage
|
|
|
|
\chapter{Introduction}
|
|
\section{Structure and operation of the electrical grid}
|
|
\subsection{Structure of the electrical grid}
|
|
\subsubsection{Generators and loads}
|
|
\subsubsection{Transformers}
|
|
\subsubsection{Tie lines}
|
|
|
|
\subsection{Operational concerns}
|
|
\subsubsection{Modelling the electrical grid}
|
|
\subsubsection{Generator controls}
|
|
\subsubsection{Load shedding}
|
|
\subsubsection{System stability}
|
|
\subsubsection{Power System Stabilizers}
|
|
|
|
\subsubsection{Smart metering}
|
|
|
|
\section{Smart meter technology}
|
|
\subsubsection{Common components}
|
|
|
|
Smart meters usually are built around a standard microcontroller. \label{sm-cpu}
|
|
\subsubsection{Cryptographic coprocessors}
|
|
\subsubsection{Physical structure}
|
|
\subsubsection{Physical installation}
|
|
|
|
\section{Regulatory frameworks around the world}
|
|
\subsection{International standards}
|
|
\subsection{The regulatory situation in selected countries}
|
|
\subsubsection{Germany}
|
|
\subsubsection{France}
|
|
\subsubsection{the UK}
|
|
\subsubsection{Italy}
|
|
\subsubsection{Northern America}
|
|
\subsubsection{Japan}
|
|
\subsection{Common themes}
|
|
|
|
\section{Security in smart grids}
|
|
The smart grid in practice is nothing more or less than an aggregation of embedded control and measurement devices that
|
|
are part of a large control system. This implies that all the same security concerns that apply to embedded systems in
|
|
general also apply to most components of a smart grid in some way. Where programmers have been struggling for decades
|
|
now with input validation\cite{leveson01}, the same potential issue raises security concerns in smart grid scenarios as
|
|
well\cite{mo01, lee01}. Only, in smart grid we have two complicating factors present: Many components are embedded
|
|
systems, and as such inherently hard to update. Also, the smart grid and its control algorithms act as a large
|
|
(partially-)distributed system, making problems such as input validation or authentication difficult to
|
|
implement\cite{blaze01} and adding a host of distributed systems problems on top\cite{lamport01}.
|
|
|
|
Given that the electrical grid is a major piece of essential infrastructure in modern civilization, these problems
|
|
amount to significant issues in practice. Attacks on the electrical grid may have grave consequences\cite{lee01} all the
|
|
while the long maintenance cycles of various components make the system slow to adapt. Thus, components for the smart
|
|
grid need to be built to a much higher standard of security than most consumer devices to ensure they live up to
|
|
well-funded attackers even decades down the road. This requirement intensifies the challenges of embedded security and
|
|
distributed systems security among others that are inherent in any modern complex technological system.
|
|
|
|
A point we will not consider in much depth is theft of electricity. A large part of the motivation of the introduction
|
|
of smart meters seems to be % TODO weak statement
|
|
to reduce the level of fraud by consumers. Academic papers tend to either focus on other benefits such as generation
|
|
efficiency gains through better forecasting or try to rationalize the funamentally anti-consumer nature of smart
|
|
metering with strenuous claims of ``enormous social benefits''\cite{mcdaniel01}. We will entirely focus on grid
|
|
stability and discard electricity theft in the context of this paper for two reasons: One, billing inaccuracies of
|
|
electricity companies are of very low urgency compared to grid stability, and the one is a precondition for the other.
|
|
Two, utility companies can already put strong bounds on the amount of theft by simply cross-refrencing meter readings
|
|
against trusted readings from upstream sections of the grid. This capability works even without smart meters and only
|
|
gains speed from smart meters, just as the old exploit of bypassing the meter with a section of wire can't be prevented
|
|
like this.
|
|
|
|
Due to these bounds on its volume, electricity theft using smart meter hacking would not scale. Hackers would simply be
|
|
rooted up one by one with no damage to consumers and very limmited damage to utility companies. Damage in these
|
|
scenarios would be a far cry from the efficiency of an exponentially growing botnet.
|
|
|
|
\subsection{Smart grid components as embedded devices}
|
|
A fundamental challenge in smart grid implementations is the central role smart electricity meters play. Smart meters
|
|
are used both for highly-granular load measurement and (in some countries) load switching\cite{zheng01}.
|
|
Smart electricity meters are effectively consumer devices. They are built down to a certain price point that is
|
|
measured by the burden it puts on consumers and that is generally fixed by regulatory authorities. % FIXME cite
|
|
This requirement precludes some hardware features such as the use of a standard hardened software environment on a
|
|
high-powerded embedded system (such as a hypervirtualized embedded linux setup) that would both increase resilience
|
|
against attacks and simplify updates. Combined with the small market sizes in smart grid deployments
|
|
\footnote{
|
|
Most vendors of smart electricity meters only serve a handful of markets. For the most part, smart meter development
|
|
cost lies in the meter's software % TODO cite?
|
|
There exist multiple competing standards applicable to various parts of a smart electricity meter. In addition,
|
|
most countries have their own certification regimen\cite{cenelec01}. This complexity creates a large development
|
|
burden for new market entrants\cite{perez01}.
|
|
}
|
|
this produces a high cost pressure on the software development process for smart electricity meters.
|
|
|
|
\subsection{The state of the art in embedded security}
|
|
Embedded security generally is much harder than security of higher-level systems. This is due to a combination of the
|
|
unique constraints of embedded devices (hard to update, usually small quantity) and their lack of capabilities
|
|
(processing power, memory protection functions, user interface devices). Even very well-funded companies continue to
|
|
have serious problems securing their embedded systems. A spectacular example of this difficulty is the recently-exposed
|
|
flaw in Apple's iPhone SoC first-stage ROM bootloader\footnote{
|
|
Modern system-on-chips integrate one or several CPUs with a multitude of peripherals, from memory and DMA
|
|
controllers over 3D graphics accelerators down to general-purpose IO modules for controlling things like indicator
|
|
LEDs. Most SoCs boot from one of several boot devices such as flash memory, ethernet or USB according to a
|
|
configuration set e.g. by connecting some SoC pins a certain way or set by device-internal write-only fuse bits.
|
|
|
|
Physically, one of the processing cores of the SoC (usually one of the main CPU cores) is connected such that it is
|
|
taken out of reset before all other devices, and is tasked with switching on and configuring all other devices of
|
|
the SoC. In order to run later intialization code or more advanced bootloaders, this core on startup runs a very
|
|
small piece of code hard-burned into the SoC in the factory. This ROM loader initializes the most basic peripherals
|
|
such as internal SRAM memory and selects a boot device for the next bootloader stage.
|
|
|
|
Apple's ROM loader performs some authorization checks, to ensure no unauthorized software is loaded. The present
|
|
flaw allows an attacker to circumvent these checks, booting code not authorized by Apple on a USB-connected iPhone,
|
|
compromising Apple's chain of trust from ROM loader to userland right at its root.
|
|
}, that allows a full compromise of any iPhone before the iPhone X. iPhone 8, one of the affected models, is still being
|
|
manufactured and sold by Apple today\footnote{
|
|
i.e. at the time this paragraph was written, on %FIXME
|
|
}. In another instance, Samsung put a flaw in their secure-world firmware used for protection of sensitive credentials
|
|
in their mobile phone SoCs in % FIXME year % .
|
|
If both of these very large companies have trouble securing parts of their secure embedded software stacks measuring a
|
|
mere few hundred bytes in Apple's case or a few kilobytes in Samsung's, what is a smart electricity meter manufacturer
|
|
to do? For their mass-market phones, these two companies have R\&D budgets that dwarf some countries' national budgets.
|
|
% FIXME hyperbole?
|
|
% FIXME cite
|
|
|
|
Since thorough formal verification of code is not yet within reach for either large-scale software development or
|
|
code heavy in side-effects such as embedded firmware or industrial control software\cite{pariente01}
|
|
the two most effective measures for embedded security is reducing the amount of code on one hand, and labour-intensively
|
|
checking and double-checking this code on the other hand. A smart electricity manufacturer does not have a say in the
|
|
former since it is bound by the official regulations it has to comply with, and will almost certainly not have sufficient
|
|
resources for the latter.
|
|
% FIXME expand?
|
|
% FIXME cite some figures on code size in smart meter firmware?
|
|
|
|
\subsection{Attack avenues in the smart grid}
|
|
If we model the smart grid as a control system responding to changes in inputs by regulating outputs, on a very high
|
|
level we can see two general categories of attacks: Attacks that directly change the state of the outputs, and attacks
|
|
that try to influence the outputs indirectly by changing the system's view of its inputs. The former would be an attack
|
|
such as one that shuts down a power plant to decrease generation capacity. The latter would be an attack such as one
|
|
that forges grid frequency measurements where they enter a power plant's control systems to provoke increasing
|
|
oscillation in the amount of power generated by the plant according to the control systems' directions.
|
|
% FIXME cite
|
|
% FIXME expand
|
|
|
|
\subsubsection{Communication channel attacks}
|
|
Communication channel attacks are attacks on the communication links between smart grid components. This could be
|
|
attacks on IP-connected parts of the core network or attacks on shared busses between smart meters and IP gateways in
|
|
substations. Generally, these attacks can be mitigated by securing the aforementioned communication links using modern
|
|
cryptography. IP links can be protected using TLS, and more low-level busses can be protected using more lightweight
|
|
Noise\cite{perrin01}-based protocols.
|
|
Cryptographic security transforms an attackers ability to manipulate communication contents into a mere denial of
|
|
service attack. Thus, in addition to cryptographic security safety under DoS conditions must be ensured to ensure
|
|
continued system performance under attacks. This safety property is identical with the safety required to withstand
|
|
random outages of components, such as communications link outages due to physical damage from storms, flooding etc.
|
|
% FIXME cite papers on attack impact, on coutermeasures and on attack realization
|
|
In general, attacks at the meter level may be hard to weaponize % may be -> weak statement?
|
|
since meters are used mostly for billing and forecasting purposes % FIXME cite
|
|
and for more critical grid control purposes there exist several additional layers of sensors above smart meters that
|
|
limit how much an attacker can falsify smart meter readings without the manipulation being obvious. In order for an
|
|
attack to have more far-reaching consequences the attacker would need to compromise additional grid
|
|
infrastructure\cite{kim01,kosut01}.
|
|
|
|
\subsubsection{Exploiting centralized control systems}
|
|
The type of smart grid attack most often cited in popular discourse, and to the author's knowledge % FIXME verify, cite
|
|
the only type that has so far been conducted in practice, is a direct attack on centralized control systems. In this
|
|
attack, computer components of control systems are compromised by the same techniques used to compromise any other kind
|
|
of computer system such as exploiting insecure services running on internet-exposed ports and using one compromised
|
|
system to compromised other systems connected with it through an ostensably secure internal network. These attacks are
|
|
very powerful as they yield the attacker direct control over whatever outputs the control systems are controlling. If an
|
|
attacker manages to compromise a power stations control computers, they may be able to influence generation output or
|
|
even cause an emergency shutdown. % FIXME
|
|
|
|
Despite their potentially large impact, these attacks are only moderately interesting from a scientific perspective. For
|
|
one, their mitigation mostly consists of a straightforward application of security practices well-known for decades.
|
|
Though there is room for the implementation of genuinely new, application-specific security systems in this field, the
|
|
general state of the art is lacking behind the rest of the computer industry such that the low-hanging fruit should take
|
|
priority. % FIXME cite this bold claim very properly
|
|
|
|
In addition, given political will these systems can readily be secured since there is only a comparatively small number
|
|
of them and driving a technician to every one of them in turn to install some security update is perfectly feasible.
|
|
|
|
\subsubsection{Control function exploits}
|
|
Control function exploits are attacks on the mathematical control loops used by the centralized control system. One
|
|
example of such an attack would be resonance attacks as described in \textcite{wu01}.
|
|
In this kind of attack, inputs from peripheral sensors indicating grid load to the centralized control system are
|
|
carefully modified to cause a disproportionally large oscillation in control system action. This type of attack relies
|
|
on complex resonance effects that arise when mechanical generators are electrically coupled. These resonances,
|
|
coloquially called ``modes'' are well-studied in power system engineering\cite{rogers01,grebe01,entsoe01}.
|
|
% FIXME: refer to section on stability control above here
|
|
Even disregarding modern attack scenarios, for stability electrical grids are designed with measures in place to dampen
|
|
any resonances inherent to grid structure. Still, requiring an accurate grid model these resonances are hard to analyze
|
|
and unlikely to be noiticed under normal operating conditions.
|
|
|
|
Mitigation of these attacks is most easily done by on the one hand ensuring unmodified sensor inputs to the control
|
|
systems in the first place, and on the other hand carefully designing control systems not to exhibit exploitable
|
|
behavior such as oscillations.
|
|
% FIXME cite mitigation approaches
|
|
|
|
\subsubsection{Endpoint exploits}
|
|
One rather interesting attack on smart grid systems is one exploiting the grid's endpoint devices such as smart
|
|
electricity meters\footnote{
|
|
Though potentially this could also aim at other kinds of devices distributed on a large scale such as sensors in
|
|
unmanned substations. % FIXME cite verify
|
|
}
|
|
These meters are deployed on a massive scale, with several thousand meters deployed for every substation.
|
|
% FIXME cite (this should be straightforward)
|
|
Thus, once compromised restoration to an uncompromised state can be potentially very difficult if it requires physical
|
|
access to thousands of devices hidden inaccessible in private homes.
|
|
|
|
By compromising smart electricity meters, an attacker can trivially forge the distributed energy measurements these
|
|
devices perform. In a best-case scenario, this might only affect billing and lead to customers being under- or
|
|
over-charged if the attack is not noticed in time. However, in a less ideal scenario the energy measurements taken by
|
|
these devices migth be used to inform the grid centralized control systems % FIXME cite
|
|
and a falsification of these measurements might lead to inefficiency.
|
|
|
|
In some countries and for some customers, these smart meters have one additional function that is highly useful to an
|
|
attacker: They contain high-current load switches to disconnect the entire household or business in case electricity
|
|
bills are left unpaid for a certain period. In countries that use these kinds of systems, the load disconnect is often
|
|
simply hooked up to one of the smart merter's central microcontroller's general-purpose IO pins, allowing anyone
|
|
compromising this microcontroller's firmware to actuate the load switch at will. % FIXME validate cite add pictures
|
|
|
|
Given control over a large number of network-connected smart meters, an attacker might thus be able to cause large-scale
|
|
disruptions of power consumption by repeatedly disconnecting and re-connecting a large number of consumers.
|
|
% FIXME cite some analysis of this
|
|
Combined with an attack method such as the resonance attack from \textcite{wu01}
|
|
that was mentioned above, this scenario poses a serious danger to grid stability.
|
|
|
|
% FIXME add small-scale load shedding for heaters etc.
|
|
|
|
\subsection{Attacker models in the smart grid}
|
|
\subsection{Practical attacks}
|
|
\subsection{Practical threats}
|
|
\subsection{Conclusion, or why we are doomed}
|
|
We can conclude that a compromise of a large number of smart electricity meters cannot be ruled out. The complexity of
|
|
network-connected smart meter firmware makes it exceedingly unlikely that it is in fact flawless. Large-scale
|
|
deployments of these devices under some circumstances such as where they are used with load disconnect relays make them
|
|
an attractive target for attackers interested in causing grid instability. The attacker model for these devices very
|
|
definitely includes enemy states, who have considerable resources at their disposal.
|
|
|
|
For a reasonable guarantee that no large-scale compromises of hard- and software built today will happen over a span of
|
|
some decades, we would have to radically simplify its design and limit attack surface. Unfortunately, the complexity of
|
|
smart electricity meter implementations mostly stems from the large list of requirements these devices have to conform
|
|
with. Additionally, standards have already been written and changes that reduce scope or functionality have become
|
|
exceedingly unlikely at this point.
|
|
|
|
A general observation with smart grid systems of any kind is that they comprise a zealous departure of the decentralized
|
|
control structure of yesterday's dumb grid and the advent of centralization at an enormous scale. This modern,
|
|
centralized infrastructure has been carefully designed to defend against malicious actors%FIXME cite
|
|
and all involved parties have an interest in keeping it secure. Still, like in any other system this centralization also
|
|
makes a very attractive target for attackers since an attacker can likewise employ this centralized control to their
|
|
goals. Fundamentally, decentralized systems tend to make attacks of any kind a lot more costly and one might question
|
|
whether security has truly been gained during smart grid rollout. % FIXME hot take maybe
|
|
|
|
\chapter{Restoring endpoint safety in an age of smart devices}
|
|
If as layed out in the previous paragraph we cannot rule out a large-scale compromise of smart energy meters, we have to
|
|
rephrase our claim to security. If we cannot rule out exploitation, we have to limit its impact. If we assume that we
|
|
cannot strip any functionality from smart meters since it may be required by standards or for enormous social
|
|
benefits\cite{mcdaniel01} % FIXME is sarcasm ok here?
|
|
all we can do is to flush out an attacker once they are in.
|
|
|
|
In a worst-case scenario an attacker would gain unconstrained code execution e.g. by exploiting a flaw in a network
|
|
protocol implentation. Since smart meters use standard microcontrollers that do not have advanced memory protection
|
|
functions (see pg. \ref{sm-cpu}), at this point we can assume the attacker has full control over the main
|
|
microcontroller. With this control they can actuate the load switch if present, transmit data through the device's
|
|
communication interfaces or use the user interface components such as LEDs and the LCD. Using the self-programming
|
|
capabilities of modern flash microcontrollers, an attacker may even gain persistency without much trouble. Note that in
|
|
systems separating cryptographic functions into some form of cryptographic module such as systems used in Germany
|
|
% TODO list other countries as well? FIXME cite BSI standard requiring this
|
|
we can be optimistic and assume the attacker has not in fact compromised this cryptographic co-processor yet and does
|
|
not have access to any cryptographic secrets yet.
|
|
|
|
Given that the attacker has complete control over the meter's core microcontroller and given that due to cost
|
|
constraints we are bound to use whatever microcontroller the meter OEM has chosen for their design, we cannot rely on
|
|
software running on the core mircocontroller to restore system integrity.
|
|
|
|
Our solution to this problem is to add another, very small microcontroller to the smart meter design. This
|
|
microcontroller will contain a small piece of software to receive cryptographically authenticated commands from utility
|
|
companies and on demand reset the meter's core microcontroller to a known-good state. We have to assume the code in the
|
|
core controller's flash memory has been compromised, so our only option to flush out an attacker is to re-program the
|
|
core microcontroller in its entirety. We propose using JTAG to re-program the core microcontroller
|
|
% TODO get terminology consistent. Is "core microcontroller" a good term here?
|
|
with a known-good firmware image read from a sufficiently large SPI flash connected to the reset controller. JTAG is
|
|
supported by most microcontrollers complex enough to end up in a smart meter design % TODO colloquialism
|
|
and given adequate documentation JTAG programming functionality can be ported to new microcontrollers with relatively
|
|
little work.
|
|
|
|
On the microcontroller side our solution requires the JTAG interface to be activated (i.e. not fused-shut) and for our
|
|
solution to work core microcontroller firmware must not be able to permanently disable the JTAG interface from within.
|
|
In microcontrollers that do not yet provide this functionality this is a minor change that could be added to a custom
|
|
microcontroller variant at low cost. On most microcontrollers keeping JTAG open should not interfere with code readout
|
|
protection. Code secrecy should be of no concern\cite{schneier01} here but besides security manufacturers have strong
|
|
preferences about this due to fear of copyright infringement.
|
|
|
|
\section{The theory of endpoint safety}
|
|
\label{sec_criteria}
|
|
In order to gain anything by adding our reset controller to the smart meter's already complex design we must satisfy two
|
|
interrelated conditions.
|
|
\begin{enumerate}
|
|
\item \textsc{security} means our reset controller itself does not have any remotely exploitable flaws
|
|
\item \textsc{safety} menas our reset controller will perform its job as intended
|
|
\end{enumerate}
|
|
|
|
Note that our \textsc{security} property includes only remote exploitation, and excludes any form of hardware attack.
|
|
Even though most smart meters provide some level of physical security, we do not wish to make any assumptions on this.
|
|
In the following section we will elaborate our attacker model and it will become apparent that sufficient physical
|
|
security to defend against all attackers in our model would be infeasible, and thus we will design our overall system
|
|
to remain secure even assuming some number of physically compromised devices.
|
|
% FIXME expand
|
|
|
|
\subsection{Attack characteristics}
|
|
The attacker model these two conditions must hold under is as follows. We assume three angles of attack: Attacks by the
|
|
customer themselves, attacks by an insider within the metering systems controlling utility company and lastly attacks
|
|
from third parties. Examples for these third parties are hobbyist hackers or outside cyber-criminals on the one hand,
|
|
but also other companies participating in the smart grid infrastructure besides the utility company such as intermediary
|
|
providers of meter-reading services.
|
|
|
|
Due to the critical nature of the electrical grid, we have to include hostile state actors in our attacker model. When
|
|
acting directly, these would be classified as third-party attackers by the above schema, but they can reasonably be
|
|
expected to be able to assume either of the other two roles as well e.g. through infiltration or bribery.
|
|
\textcite{fraunholz01} in their elaboration of their generalized attacker model give some classification of attackers
|
|
and provide a nice taxonomy of attacker properties. In their threat/capability rating, criminals are still considered
|
|
to have higher threat rating than state-sponsored attackers. The New York Times reported in 2016 that some states
|
|
recruit their hacking personnel in part from cyber-criminals. If this report is true, in a worst-case scenario we have
|
|
to assume a state-sponsored attacker to be the worst of both types. Comparing this against the other attacker types in
|
|
\textcite{fraunholz01}, this state-sponsored attacker is strictly worse than any other type in both variables. We are
|
|
left with a highly-skilled, very well-funded, highly intentional and motivated attacker.
|
|
|
|
Based on the above classification of attack angles and our observations on state-sponsored attacks, we can adapt
|
|
\textcite{fraunholz01} to our problem, yielding the following new attacker types:
|
|
|
|
\begin{enumerate}
|
|
\item \textbf{Utility company insiders controlled by a state actor}
|
|
We can ignore the other internal threats described in \textcite{fraunholz01} since an insider cooperating with a
|
|
state actor is strictly worse in every respect.
|
|
\item \textbf{State-sponsored external attackers}
|
|
A state actor can obviously directly attack the system through the internet.
|
|
\item \textbf{Customers controlled by a state actor}
|
|
A state actor can very well compromise some customers for their purposes. They might either physically
|
|
infiltrate the system posing as legitimate customers, or they might simply deceive or bribe existing customers
|
|
into cooperation.
|
|
\item \textbf{Regular customers}
|
|
Though a hostile state actor might gain control of some number of customers through means such as voluntary
|
|
cooperation, bribery, infiltration, they are limited in attack scale since they do not want to arouse premature
|
|
attention. Though regular customers may not have the motivation, skill or resources of a state-sponsored
|
|
attacker, potentially large numbers of them may try to attack a system out of financial incentives. To allow for
|
|
this possibility, we consider regular customers separate from state actors posing as customers in some way.
|
|
\end{enumerate}
|
|
|
|
\subsection{Overall structural system security}
|
|
Considering overall security, we first introduce the \emph{reset authority}, a trusted party acting as the single
|
|
authority for issuing reset commands in our system. In practice this trusted party may be part of the utility company,
|
|
part of an external regulatory body or a hybrid setup requiring both to cooperate. We assume this party will be designed
|
|
to be secure against all of the above attacker types. The precise design of this trusted party is out of scope for this
|
|
work but we will list some practical suggestions on how to achieve security below. % FIXME do the list
|
|
% FIXME put up a large box on this limitation
|
|
|
|
Using an asymmetric cryptographic design centered around the \emph{reset authority}, we rule out all attacks except for
|
|
denial-of-service attacks on our system by any of the four attacker types. All reset commands in our system originate
|
|
from the \emph{reset authority} and are cryptographically secured to provide authentication and tamper detection.
|
|
Under this model, attacks on the electrical grid components between the \emph{reset authority} and the customer device
|
|
degrade into man-in-the-middle attacks. To ensure the \textsc{safety} criterion from \ref{sec_criteria} holds we must
|
|
% FIXME check whether this \ref displays as intended
|
|
make sure our cryptography is secure against man-in-the-middle attacks and we must try to harden the system against
|
|
denial-of-service attacks by the attacker types listed above. Given our attacker model we cannot fully guard against
|
|
this sort of attack but we can at least choose a commmunication channel that is resilient against denial of service
|
|
attacks under the above model.
|
|
|
|
Finally, we have to consider the issue of hardware security. We will solve the problem of physical attacks on some small
|
|
number of devices by simply not programming any secret information into these devices. This also simplifies hardware
|
|
production. From consideration in this work we explicitly rule out any form of supply-chain attack as
|
|
out-of-scope.
|
|
% FIXME include considerations on production testing somewhere (is the device working? is the right key programmed?)
|
|
|
|
\subsection{Complex microcontroller firmware}
|
|
The \textsc{security} property from \ref{sec_criteria} is in a large part reliant on the security of our reset
|
|
controller firmware. The best method to increase firmware security is to reduce attack surface by limiting external
|
|
interfaces as much as possible and by reducing code complexity as much as possible.
|
|
% FIXME formalize this as something like "Design Goal DG-023-42-1" ?
|
|
If we avoid the complexity of most modern microcontroller firmware we gain another benefit beyond implicitly reduced
|
|
attack surface: If the resulting design is small enough we may attempt formal verification of our security property.
|
|
Though formal verification tools are not yet suitable for highly complex tasks they are already barely adequate for
|
|
small amounds of code and simple interfaces.
|
|
|
|
\subsection{Modern microcontroller hardware}
|
|
Microcontrollers have gained enormously in both performance/efficiency as well as in peripheral support. Alas, these
|
|
gains have largely been driven by insatiable customer demand for faster, more powerful chips and for a long time
|
|
security has not been considered important outside of some specific niches such as smartcards. Traditionally a
|
|
microcontroller would spend its entire lifetime without ever being exposed to any networks. Though this trend has been
|
|
reversing with the increasing adoption of internet-of-things things
|
|
and more advanced security features have started appearing in general-purpose microcontrollers, most still lack even
|
|
basic functionality found in processors for computers or smartphones.
|
|
|
|
One of the components lacking from most microcontrollers is strong memory protection or even a memory mapping unit as
|
|
it is found in all modern computer processors and SoCs for applications such as smartphones. Without an MPU/MPU some
|
|
mitigations for memory safety violations cannot be implemented. This and the absence of virtualization tools such as
|
|
ARM's TrustZone make hardening microcontroller firmware a big task. It is very important to ensure memory safety in
|
|
microcontroller firmware through tools such as defensive coding, extensive testing and formal verification.
|
|
|
|
In our design we achieve simplicity on two levels: One, we isolate the very complex metering firmware from our reset
|
|
controller by having both run on separate microcontrollers. Two, we keep the reset controller firmware itself extremely
|
|
simple to reduce attack surface there.
|
|
|
|
\subsection{Regulatory and economical constraints}
|
|
\subsection{Safety vs. Security: Opting for restoration instead of prevention}
|
|
|
|
|
|
\subsection{Technical outline of a safety reset system}
|
|
|
|
\section{Communication channels on the grid}
|
|
|
|
There is a number of well-established technologies for communication on or along power lines. We can distinguish three
|
|
basic system categories: Systems using separate wires (such as DSL over landline telephone wiring), wireless radio
|
|
systems (such as LTE) and \emph{powerline communication} (PLC) systems that re-use the existing mains wiring and
|
|
superimpose data transmissions on the 50 Hz mains sine\cite{gungor01,kabalci01}.
|
|
|
|
For our scenario, we will ignore short-range communication systems. There exists a large number of \emph{wideband}
|
|
powerline communication systems that are popular with consumers for bridging ethernet between parts of an apartment or
|
|
house. These systems transmit at up to several hundred megabits over distances up to several tens of
|
|
meters\cite{kabalci01}. Technologically, these wideband PLC systems are very different from \emph{narrowband} systems
|
|
used by utilities for load management among other applications and they are not relevant to our analysis.
|
|
|
|
\subsection{Powerline communication (PLC) systems and their use}
|
|
In long-distance communications for applications such as load management, PLC systems are attractive since they allow
|
|
re-using the existing wiring infrastructure and have been used as early as in the 1930s\cite{hovi01}. Narrowband PLC
|
|
systems are a potentially low-cost solution to the problem of transmitting data at small bandwidth over distances of
|
|
several hundred meters up to tens of kilometers.
|
|
|
|
Narrowband PLC systems transmit on the order of kilobits per second or slower. A common use of this sort of system are
|
|
\emph{ripple control} systems. These systems superimpose a low-frequency signal at some few hundred Hertz carrier
|
|
frequency on top of the 50Hz mains sine. This low-frequency signal is used to encode switching commands for
|
|
non-essential residential or industrial loads. Ripple control systems provide utilities with the ability to actively
|
|
control demand while promising small savings in electricity cost to consumers\cite{dzung01}.
|
|
|
|
In any PLC system there is a strict tradeoff between bandwidth, power and distance. Higher bandwidth requires higher
|
|
power and reduces maximum transmission distance. Where ripple control systems usually use few transmitters to cover
|
|
the entire grid of a regional distribution utility, higher-bandwidth bidirectional systems used for automatic meter
|
|
reading (AMR) in places such as italy or france require repeaters within a few hundred meters of a transmitter.
|
|
|
|
\subsection{Landline and wireless IP-based systems}
|
|
Especially in automated meter reading (AMR) infrastructure the cost-benefit tradeoff of powerline systems does not
|
|
always work out for utilities. A common alternative in these systems is to use the public internet for communication.
|
|
Using the public internet has the advantage of low initial investment on the part of the utility company as well as
|
|
quick commissioning. Disadvantages compared to a PLC system are potentially higher operational costs due to recurring
|
|
fees to network providers as well as lower reliability. Being integrated into power grid infrastructure, a PLC system's
|
|
failure modes are highly correlated with the overall grid. Put briefly, if the PLC interface is down, there is a good
|
|
chance that power is out, too. In contrast to this general internet services exhibit a multitude of failures that are
|
|
entirely decorrelated from power grid stability.
|
|
|
|
For purposes such as meter reading for billing purposes, this stability is sufficient. However for systems that need to
|
|
hold up in crisis situations such as the recovery system we are contemplating in this thesis, the public internet may
|
|
not provide sufficient reliability.
|
|
|
|
\subsection{Proprietary wireless systems}
|
|
% FIXME
|
|
|
|
\subsection{Frequency modulation as a communication channel}
|
|
|
|
For our system, we chose grid frequency modulation (henceforth GFM) as a low-bandwidth uni-directional broadcast
|
|
communications channel. Compared to traditional PLC GFM requires only a small amount of additional hardware, works
|
|
reliably throughout the grid and is harder to manipulate by a malicious actor.
|
|
|
|
Grid frequency in europe's synchronous areas is nominally 50 Hertz, but there are small load-dependent variations from
|
|
this nominal value. Any device connected to the power grid (or even just within physical proximity of power wiring) can
|
|
reliably and accurately measure grid frequency at low hardware overhead. By intentionally modifying grid frequency, we
|
|
can create a very low-bandwidth broadcast communication channel. Grid frequency modulation has only ever been proposed
|
|
as a communications channel at very small scales in microgrids before\cite{urtasun01} but to our knowledge has not yet
|
|
been considered for large-scale application.
|
|
|
|
Advantages of using grid frequency for communication are low receiver hardware complexity as well as the fact that a
|
|
single transmitter can cover an entire synchronous area. Though the transmitter has to be very large and powerful, setup
|
|
of a single large transmitter faces lower bureaucratic hurdles than integration of hundreds of smaller ones into
|
|
hundreds of local systems each with autonomous goverance.
|
|
|
|
\subsubsection{The frequency dependance of grid frequency}
|
|
% FIXME find a solid citation on this
|
|
|
|
\subsubsection{Control systems coupled to grid frequency}
|
|
|
|
\subsubsection{Avoiding dangerous modes}
|
|
|
|
Modern power systems are complex electromechanical systems. Each component is controlled by several carefully tuned
|
|
feedback loops to ensure voltage, load and frequency regulation. Multiple components are coupled through transmission
|
|
lines that themselves exhibit complex dynamic behavior. The overall system is generally stable, but may exhbit some
|
|
instabilities to particular small-signal stimuli. These instabilities, called \emph{modes} occur when due to mis-tuning
|
|
of parameters or physical constraints the overall system exhibits oscillation at particular frequencies.
|
|
\textcite{kundur01} splits these into four categories:
|
|
|
|
\begin{description}
|
|
\item[Local modes] where a single power station oscillates in some parameter
|
|
\item[Interarea modes] where subsections of the overall grid oscillate w.r.t.\ each other due to weak coupling
|
|
between them
|
|
\item[Control modes] caused by imperfectly tuned control systems
|
|
\item[Torsional modes] that originate from electromechanical oscillations in the generator itself
|
|
\end{description}
|
|
|
|
The oscillation frequencies associated with each of these modes are usually between a few tens of Millihertz and a few
|
|
Hertz, see for example \textcite{grebe01} and \textcite{entsoe01}. It is hard to predict the particular modes of a
|
|
power system at the scale of the central-european interconnected system. Theoretical analysis and simulation may give
|
|
rough indications but cannot yield conclusive results. Due to the obvious danger as well as high economical impact due
|
|
to inefficiencies experimental measurements are infeasible. Finally, modes are highly dependent on the power grid's
|
|
structure and will change with changes in the power grid over time. For all of these reasons, a grid frequency
|
|
modulation system must be designed very conservatively without relying on the absence (or presence) of modes at
|
|
particular frequencies. A concrete design guideline that we can derive from this situation is that the frequency
|
|
spectrum of any grid frequency modulation system should not exhibit any notable peaks and should avoid a concentration
|
|
of spectral energy in certain frequency ranges. On the one hand this rules out some modulation schemes. On the other
|
|
hand it provides us with a useful pointer towards those techniques that might work well: Spread-spectrum techniques. By
|
|
employing spread-spectrum modulation we can produce an almost ideal frequency-domain behavior while at the same time
|
|
achieving some modulation gain, increasing system sensitivity.
|
|
|
|
By using spread-spectrum techniques we can spread the energy of our modulation over a maximum in
|
|
bandwidth\cite{goiser01}. The coding gain spread-spectrum techniques yield potentially allows for a weaker excitation,
|
|
thereby allowing further reduction of the probability of disturbance to the overall system. Spread-spectrum techniques
|
|
also inherently allow a tradeoff between receiver sensitivity and data rate which is a highly useful parameter to have
|
|
for the overall system design.
|
|
|
|
\subsubsection{Overall system parameters}
|
|
\subsubsection{An outline of practical implementation}
|
|
|
|
\section{From grid frequency to a reliable communications channel}
|
|
\subsection{Channel properties}
|
|
|
|
|
|
\subsection{Modulation and its parameters}
|
|
|
|
|
|
\subsection{Error-correcting codes}
|
|
|
|
|
|
\subsection{Cryptographic security}
|
|
|
|
Informally the system we are looking for can be modelled as consisting of three parties: The trusted
|
|
\textsc{Transmitter}, one of a large number of untrusted \textsc{Receivers}, and an \textsc{Attacker} according to the
|
|
following rules:
|
|
|
|
\begin{enumerate}
|
|
\item \textsc{Transmitter} and \textsc{Attacker} can both transmit any bit sequence
|
|
\item \textsc{Receiver} receives any transmission by either \textsc{Transmitter} or \textsc{Attacker} but cannot
|
|
distinguish between the two on the signal level
|
|
\item \textsc{Attacker} knows anything a \textsc{Receiver} might know
|
|
\item \textsc{Transmitter} is stronger than \textsc{Attacker} and will ``win'' in simultaneous transmission
|
|
\item Both \textsc{Transmitter} and \textsc{Receiver} can be seeded with some information on each other such as
|
|
public key fingerprints.
|
|
\end{enumerate}
|
|
|
|
We are not interested in congestion scenarios where an attacker attempts to disrupt an ongoing transmission by the
|
|
transmitter. In practice there are several avenues to prevent such attempts including the following. Compromised loads
|
|
that are being abused by the attacker can be manually disconnected by the utility. Error-correcting codes can be used to
|
|
provide resiliency against small-scale disturbances. Finally, the transmitter can be designed to have high enough power
|
|
to be able to override any likely attacker.
|
|
|
|
Our goal is to find a cryptographic primitive that has the following properties:
|
|
\begin{enumerate}
|
|
\item \textsc{Transmitter} can produce a transmission bit sequence $\mathbf{s}$ (or equivalently a set of such
|
|
sequences) that \textsc{Receiver} can uniquely identify as being generated by \textsc{Transmitter}:
|
|
$\mathcal{R}\left(\mathbf{s}\right) = 1$. Upon reception of this sequence, \textsc{Receiver} performs the safety
|
|
reset.
|
|
\item \textsc{Attacker} cannot forge $\mathbf{s}$, that is find $\mathbf{s}'$ such that
|
|
$\mathbf{s} \neq \mathbf{s}' \land \mathcal{R}\left(\mathbf{s}'\right) = 1$
|
|
\item Our system conforms to an at-most-once semantic. That is, upon transmission of a valid bit sequence coded for
|
|
a particular \textsc{Receiver} or set of receivers each one either performs exactly one safety reset or none at
|
|
all. We cannot achieve an exactly-once semantic since we are using an unidirectional lossy communication
|
|
primitive. More coloquially, \textsc{Receiver} might be offline due to a localized power outage and might thus
|
|
not hear \textsc{Transmitter} even if our broadcast primitive is reliable. The practical impact of this
|
|
limitation can be mitigated by transmitter simply repeating itself until the desired effect has been achieved.
|
|
\end{enumerate}
|
|
|
|
An important limitation from the rules of our setup above is that \textsc{Attacker} can always record the bit sequence
|
|
\textsc{Transmitter} transmits and replay that same sequence later. Before considering any cryptographic approaches we
|
|
can make the preliminary observation that we can trivially prevent \textsc{Attacker} from violating the
|
|
at-most-once criterion by simply requiring \textsc{Receiver} to memorize all bit sequences that have been transmitted
|
|
thus far and only reacting to new bit sequences. This means an attacker might be able to cause offline receivers to
|
|
reset at a later point, but considering our goal is to reset them in the first place this would not pose a danger to the
|
|
system.
|
|
% FIXME elaborate why this is not a threat, and possible mitigations
|
|
|
|
As it seems we need a cryptographic primitive that looks somewhat like a signature. Different from a signature however,
|
|
we have somewhat relaxed constraints here: While cryptographic signatures need to work over arbitrary inputs, all we
|
|
want to ``sign'' here is the instruction to perform a safety reset. Since this is the only message we might ever want to
|
|
transmit, our message space has only one entry and thus the informational content of our message is 0 bit! All the
|
|
information we want to transmit is already encoded \emph{in the fact that we are transmitting}, and we do not require
|
|
any further payload to be transmitted. This means we can omit the entirety of the message and just transmit whatever
|
|
``signature'' we produce. This is useful since we have to conserve transmission bits so our transmissions do not take
|
|
exceeedingly long time over our extremely slow communication channel.
|
|
|
|
We could use any of several traditional asymmetric cryptographic primitives to produce these signatures. The
|
|
comparatively high computational effort required for signature verification would not be an issue. Transmissions take
|
|
several minutes anyway and we can afford to spend some tens of seconds even in signature verification. Transmission
|
|
length and by proxy system latency would be determined by the length of the signature. For RSA signature length is the
|
|
modulus length (i.e. larger than 1000 bit for even basic contemporary security). For elliptic curve-based systems
|
|
signature size is approximately twice the curve length (i.e. ~300 bit for contemporary security). However, we can do
|
|
better than this: We can exploit the strange nature of our setting that our effective message entropy is 0 bit to derive
|
|
a more efficient scheme.
|
|
|
|
\subsubsection{Lamport signatures}
|
|
|
|
In 1979, \textcite{lamport02} introduced a signature scheme that is based only on a one-way function such as a
|
|
cryptographic hash function. The basic observation is that by choosing a random secret input to a one-way function and
|
|
publishing the output, one can later prove knowledge of the input by simply publishing it. In the following paragraphs
|
|
we will describe a construction of a one-time signature scheme based on this observation. The scheme we describe is the
|
|
one usually called a ``Lamport Signature'' in modern literature and is slightly different from the variant described in
|
|
the 1979 paper, but for our purposes we can consider both to be equivalent.
|
|
|
|
\paragraph{Setup.} In a Lamport signature, for an n-bit hash function $H$ the signer generates a private key $s =
|
|
\left(s_{b, i} | b\in\left\{0, 1\right\}, 0\le i<n\right)$ of $2n$ random strings of length $n$. The signer publishes a
|
|
public key $p = \left(p_{b, i} = H\left(s_{b, i}\right), b\in\left\{0, 1\right\}, 0\le i<n\right)$ that is simply the
|
|
list of hashes of each of the random strings that make up the private key.
|
|
|
|
\paragraph{Signing.} To sign a message $m$, the signer publishes the signature $\sigma = \left(\sigma_i = k_{H(m)_i,
|
|
i}\right)$ where $H(m)_i$ is the $i$-th bit of $H$ applied to $m$. That is, for the $i$-th bit of the message's hash
|
|
$H(m)$ the signer publishes either of $p_{0, i}$ or $p_{1, i}$ depending on the hash bit's value, keeping the other
|
|
entry of $P$ secret.
|
|
|
|
\paragraph{Verification.} The verifier can compute $H(m)$ themselves and check the corresponding entries $\sigma_i =
|
|
k_{H(m)_i}$ of $S$ correctly evaluate to $p_{b, i} = H\left(s_{b, i}\right)$ from $P$ under $H$.
|
|
|
|
The above scheme is a one-time signature scheme only. After one signature has been published for a given key, the
|
|
corresponding key must not be re-used for other signatures. This is intutively clear as we are effectively publishing
|
|
part of the private key as the signature, and if we were to publish a signature for another message an attacker could
|
|
derive additional signatures by ``mixing'' the two published signatures.
|
|
|
|
\subsubsection{Winternitz Signatures}
|
|
An improvement to basic Lamport signatures as described above are Winternitz signatures as detailed in
|
|
\textcite{merkle01} and \textcite{dods01}. Winternitz signatures reduce public key length as well as signature length
|
|
for hash length $n$ from $2n$ to $\mathcal O \left(n/t\right)$ for some choice of parameter $t$ (usually a small number
|
|
such as 4).
|
|
|
|
\paragraph{Setup.} The signer generates a private key $s = \left(s_i\right)$ consisting of $\ceil{\frac{n}{t}}$ random
|
|
bit strings. The signer publishes a public key $p = \left(H^{2^t}\left(s_i\right)\right)$ where each element
|
|
$H^{2^t}\left(s_i\right)$ is the $2^t$-fold recursive application of $H$ to $s_i$.
|
|
|
|
\paragraph{Signing.} The signer splits $m$ padded to a multiple of $t$ bits into $\ceil{\frac{n}{t}}$ chunks $m_i$ of
|
|
$t$ bit each. The signer publishes the signature $\sigma = \left( \sigma_i = H^{m_i}\left(s_i\right) \right)$.
|
|
|
|
\paragraph{Verification.} The verifier can calculate for each $\sigma_i = H^{m_i}\left(s_i\right)$ that $H^{2^t -
|
|
m_i}\left(\sigma_i\right) = H^{2^t - m_i}\left(H^{m_i}\left(s_i\right)\right) = H^{2^t - m_i + m_i} \left(s_i\right) =
|
|
p_i$.
|
|
|
|
To prevent an attacker from forging additional signatures from one signature by calculating $\sigma_i' =
|
|
H\left(\sigma_i\right)$ matching $m_i' = m_i + 1$, this scheme is usually paired with a simple checksum as described in
|
|
\textcite{merkle01}.
|
|
|
|
\subsubsection{Using hash-based signatures for trigger authentication}
|
|
The most basic possible trigger authentication scheme would be to simply generate a random bit string secret key $s$ and
|
|
publish $p = H(s)$ for some hash function $H$. To activate the trigger, $\sigma = s$ would be published and listeners
|
|
could verify that $H(\sigma) = p = H(s)$. This simplistic scheme has one main disadvantage: It is a fundamentally
|
|
one-time construction. To prevent an attacker from re-triggering a listener a second time by replaying a valid trigger
|
|
$\sigma$ all listeners have to blacklist any ``used'' $\sigma$. Alas, this means we can only ever trigger a listener
|
|
\emph{once}. The good part is that any listener that missed this trigger can still be triggered later, but the bad part
|
|
is that once $s$ is burned we are out of options. The trivial solution to this would be to simply inform each listener
|
|
with a whole list of public keys in advance. This however takes $n$ times the amount of space for $n$-fold
|
|
retriggerability. Luckily we can easily derive a scheme that yields $n$-fold retriggerability while using no more same
|
|
space than the original scheme by taking some inspiration from Winternitz signatures above.
|
|
|
|
In this scheme the secret key $s$ is still a random bit string. The public key is $p = H^n(s)$ for n-times
|
|
retriggerability. The $i$-th time the trigger is activated, $\sigma_i = H^n-i(s)$ is published, and every listener can
|
|
verify that $\sigma_{i-1} = H\left(\sigma_i\right)$ with $\sigma_0 = p$. In case a listener missed one or more previous
|
|
triggers it can simply continue computing $H\left(H\left(\sigma_i\right)\right)$ and
|
|
$H\left(H\left(H\left(\sigma_i\right)\right)\right)$ until either reaching the $n$-th recursion level (indicating an
|
|
invalid signature) or finding $H^n\left(\sigma_i\right) = \sigma_j$ with $sigma_j$ being the last signature this
|
|
listener recorded, or $p$ in case there is none.
|
|
|
|
This scheme provides replay protection through listeners memorizing the last signature they activated to. Public key
|
|
length is equal to the length of the hash function $H$ used. Even for our embedded systems use case $n$ can
|
|
realistically be up to $\mathcal O\left(10^3\right)$, which is easily enough for our application.
|
|
|
|
% FIXME here and in previous ~2 pages get transmitter/receiver and sender/listener terminology straight. Also perhaps do
|
|
% some sort of scenario definition introducing those terms somewhere.
|
|
|
|
\chapter{Practical implementation}
|
|
\section{Cryptographic validation}
|
|
|
|
\section{Data collection for channel validation}
|
|
|
|
To design a solid system we needed to parametrize mains frequency variations under normal conditions. To set modulation
|
|
amplitude as well as parameters of our modulation scheme we need a frequency spectrum of mains frequency variations
|
|
(that is $\mathcal F\left(f(V(t))\right)$: Taking mains frequency $f(x)$ as a variable, the frequency spectrum of that
|
|
variable, as opposed to the frequency spectrum of mains voltage $V(t)$ itself).
|
|
|
|
\subsection{Grid Frequency Estimation}
|
|
\label{frequency_estimation}
|
|
In commercial power systems Phasor Measurement Units (PMUs) are used to precisely measure parameters of a mains voltage
|
|
waveform. One of the parameters PMUs measure is mains frequency. PMUs are used as part of SCADA systems controlling
|
|
transmission networks to characterize the operational state of the network.
|
|
|
|
From a superficial viewpoint measuring mains frequency might seem like a simple problem. Take the mains voltage
|
|
waveform, measure time between two rising-edge (or falling-edge) zero-crossings and take the inverse $f = t^{-1}$. In
|
|
practice, phasor measurement units are significantly more complex than this. This discrepancy is due to the unhealthy
|
|
% FIXME is this pun ok?
|
|
combination of both high precision and quick response that is demanded from these units. High precision is necessary
|
|
since variations of mains frequency under normal operating conditions are quite small--in the range of $5-10 \text{mHz}$
|
|
over short intervals of time. Relative to the nominal $50 \text{Hz}$ this is a derivation of less than $100 \text{ppm}$.
|
|
Relative to the corresponding $20 \text{ms}$ period that means a time derivation of about $2 \mu\text{s}$ from cycle to
|
|
cycle. From this it is already obvious why a simplistic measurement cannot yield the required precision for manageable
|
|
averaging times--we would need either a ADC sampling rate in the order of megabits or for a reconstruction through
|
|
interpolated readings an impractically high ADC resolution.
|
|
|
|
Detail on the inner workings of commercial phasor measurement units is scarce but given their essential role to SCADA
|
|
systems there is a large amount of academic research on such algorithms\cite{narduzzi01,derviskadic01}. A popular
|
|
approach to these systems is to perform a Short-Time Fourier Transform (STFT) on ADC data sampled at high sampling rate
|
|
(e.g. $10 \text{kHz}$) and then perform some analysis on the frequency-domain data to precisely locate the strong peak
|
|
around $50 \text{Hz}$. A key observation here is that FFT bin size is going to be much larger than required frequency
|
|
resolution. This fundamental limitiation follows from the nyquist criterion %FIXME maybe cite? and if we had to process
|
|
an \emph{arbitrary} signal this would highly limit our practical measurement accuracy
|
|
\footnote{
|
|
Some software packages providing FFT or STFT primitives such as scipy\cite{virtanen01} allow the user to
|
|
super-sample FFT output by specifying an FFT width larger than input data length, padding the input data with zeros
|
|
on both sides. Note that in line with Nyquist this \emph{does not} actually provide finer output resolution but
|
|
instead just amounts to an interpolation between output bins. Depending on the downstream analysis algorithm it may
|
|
still be sensible to use this property of the DFT for interpolation, but in general it will be computationally
|
|
expensive compared to other interpolation methods and in any case it will not yield any better frequency resolution
|
|
aside from a hypothetical numerical advantage\cite{gasior02}.
|
|
}.
|
|
For this reason all approaches to mains frequency estimation are based on a model of the mains voltage waveform.
|
|
Nominally, this waveform would be a perfect sine at $f = 50 \text{Hz}$. In practice it is a sine at $f \approx 50
|
|
\text{Hz}$ superimposed with some aperiodic noise (e.g. irregular spikes from inductive loads being energized) as well
|
|
as harmonic distortion that is caused by grid-topologically nearby devices with power factor
|
|
\footnote{
|
|
Power factor is a power engineering term that is used to describe how close the current waveform of a load is to
|
|
that of a purely resistive load. Given sinusoidal input voltage $V(t) = V_\text{pk} \sin \paren{\omega_\text{nom}
|
|
t}$ with $\omega_\text{nom} = 2 \pi f_\text{nom} = 2 \pi \cdot 50 \text{Hz}$ being the nominal angular frequency,
|
|
the current waveform of a resistor with resistance $R \left[\Omega\right]$ according to Ohm's law would be $I(t) =
|
|
\frac{V(t)}{R} = \frac{1}{R} V_\text{pk} \sin\paren{\omega_\text{nom} t}$. In this case voltage and current are
|
|
perfectly in phase, i.e. the current at time $t$ is linear in voltage at constant factor $\frac{1}{R}$.
|
|
|
|
In contrast to this idealized scenario reality provides us with two common issues: One, the load may be reactive.
|
|
This means its current waveform is an ideal sinusoid, but there is a phase difference between mains voltage and load
|
|
current like so: $I(t) = \frac{V(t)}{R} = \frac{1}{\left|Z\right|} V_\text{pk} \sin\paren{\omega_\text{nom} t +
|
|
\varphi}$ $Z$ would be the load's complex impedance combining inductive, capacitive and resistive components and
|
|
$\varphi$ the phase difference between the resulting current waveform and the mains voltage waveform. A common case
|
|
of such loads are motors and the inductive ballasts in old fluorescent lighting fixtures.
|
|
|
|
The second potential issue are loads with non-sinusoidal current waveform. There are many classes of these but the
|
|
most common one are switching-mode power supplies. Most SMPS for modern electronic devices have an input stage
|
|
consisting of a bridge rectifier followed by a capacitor that provide high-voltage DC power to the following
|
|
switch-mode convert circuit. This rectifier-capacitor input stage under normal load draws a high current only at the
|
|
very peak of the input voltage sinusoid and draws almost zero current for most of the period.
|
|
|
|
These two cases are measured by \emph{displacement power factor} and \emph{distortion power factor} that when
|
|
combined yield the overall true power factor. The power factor is a key quantity in the design and operation of the
|
|
power grid since a high power factor (close to $1.0$ or an in-phase sinusoidal current waveform) yields lowest
|
|
transmission and generation losses.
|
|
}
|
|
$\cos \theta \neq 1.0$. Under a continous fourier transform over a long period the frequency spectrum of a signal
|
|
distorted like this will be a low noise floor depending mainly on aperiodic noise on which a comb of harmonics as well
|
|
as some sub-harmonics of $f \approx f_\text{nom} = 50Hz$ rides. The main peak at $f \approx f_\text{nom}$ will be very
|
|
strong with the harmonics being approximately an order of magnitude weaker in energy and the noise floor being at least
|
|
another order of magnitude weaker. See figure \ref{mains_voltage_spectrum} for a measured spectrum. This domain
|
|
knowledge about the expected frequency spectrum of the signal can be employed in a number of interpolation techniques to
|
|
re-construct the precise frequency of the spectrum's main component despite comparatively coarse STFT resolution and
|
|
despite numerous distortions.
|
|
|
|
\begin{figure}
|
|
\centering
|
|
\includegraphics{../lab-windows/fig_out/mains_voltage_spectrum}
|
|
\caption{Fourier transform of an 8 hour capture of mains voltage. Data was captured using our frequency measurement
|
|
sensor described in section \ref{sec-fsensor} and FFT'ed after applying a blackman window. Vertical lines indicate
|
|
$50 \text{Hz}$ and odd harmonics.}
|
|
\label{mains_voltage_spectrum}
|
|
\end{figure}
|
|
|
|
Published grid frequency estimation algorithms such as \textcite{narduzzi01} or \textcite{derviskadic01} are rather
|
|
sophisticated and use a combination of techniques to reduce numerical errors in FFT calculation and peak fitting. Given
|
|
that we do not need reference standard-grade accuracy for our application we chose to start with a very basic algorithm
|
|
instead. We chose to use a general approach developed by experimental physicists at CERN that is described by
|
|
\textcite{gasior01}. This approach assumes a general sinusoidal signal superimposed with harmonics and broadband noise.
|
|
Applicable to a wide spectrum of practical signal analysis tasks it is a reasonable first-degree approximation of the
|
|
much more sophisticated estimation algorithms developed specifically for power systems. Some algorithms have components
|
|
such as kalman filters\cite{narduzzi01} that require a phyiscal model. As a general algorithm from \textcite{gasior01}
|
|
does not require this kind of application-specific tuning, eliminating one source of error.
|
|
|
|
\subsection{Frequency sensor hardware design}
|
|
\label{sec-fsensor}
|
|
Our safety reset controller % FIXME is this the right term?
|
|
will have to measure mains frequency to later demodulate a reset signal transmitted through it. Since we have decided to
|
|
do our own frequency measurement system here we can use this frequency measurement setup as a prototype for the
|
|
frequency measurement subcomponent of the demodulation system we will later develop. Since we do not plan to do a
|
|
large-scale field deployment of our measurement setup we can keep the hardware implementation simple by moving most of
|
|
the signal processing to a regular computer and concentrating our hardware efforts on raw signal capture.
|
|
|
|
\begin{figure}
|
|
\begin{center}
|
|
\begin{tikzpicture}[start chain = going below, node distance = 12mm and 50mm, every join/.style = {norm}]
|
|
\tikzset{
|
|
base/.style = {draw, on chain, on grid, align=center, minimum height = 4ex, font=\footnotesize},
|
|
text/.style = {base},
|
|
component/.style = {base, rectangle, text width=40mm},
|
|
coord/.style = {coordinate, on chain, on grid, node distance=6mm and 25mm}
|
|
}
|
|
\node[text centered] (input) {Single-Phase Mains Input};
|
|
\node[component] (safety) [below = of input] {Input Protection};
|
|
\node[coord] (safety-anchor) [below = of safety] {};
|
|
\node[component] (analog) [below = of safety-anchor] {Analog Signal Processing};
|
|
\node[component] (powersupply) [left = of analog] {Power supply};
|
|
\node[component] (adc) [below = of analog] {ADC};
|
|
\node[component] (micro) [below = of adc] {Microcontroller};
|
|
\node[component] (isol) [below = of micro] {Galvanic Digital Isolation};
|
|
\node[coord] (isol-left) [left = 6cm of isol.west] {};
|
|
\node[coord] (isol-right) [right = 1cm of isol.east] {};
|
|
\node[component] (usb) [below = of isol] {USB interface};
|
|
|
|
\draw[->] (input.south) -- (safety.north);
|
|
\draw[-] (safety.south) -- (safety-anchor);
|
|
\draw[->] (safety-anchor) -| (powersupply.north);
|
|
\draw[->] (safety-anchor) -| (analog.north);
|
|
\draw[->] (powersupply.south) |- (adc.west);
|
|
\draw[->] (powersupply.south) |- (micro.west);
|
|
\draw[->] (analog.south) -- (adc.north);
|
|
\draw[->] (adc.south) -- (micro.north);
|
|
\draw[->] (micro.south) -- (isol.north);
|
|
\draw[->] (isol.south) -- (usb.north);
|
|
|
|
\draw[dashed] (isol.west) -- (isol-left.east);
|
|
\draw[dashed] (isol.east) -- (isol-right.west);
|
|
\end{tikzpicture}
|
|
\end{center}
|
|
\caption{Frequency sensor hardware diagram}
|
|
\label{fmeas-sens-diag}
|
|
\end{figure}
|
|
|
|
An overall block diagram of our system is shown in fig. \ref{fmeas-sens-diag}. The mircrocontroller we chose is an
|
|
\texttt{STM32F030F4P6} ARM Cortex-M0 microcontroller made by ST Microelectronics. The ADC in fig. \ref{fmeas-sens-diag}
|
|
in our design is the integrated 12-bit ADC of this microcontroller, which is sufficient for our purposes. The USB
|
|
interface is a simple USB to serial converter IC (\texttt{CH340G}) and the galvanic digital isolation is accomplished
|
|
with a pair of high-speed optocouplers on its \texttt{RX} and \texttt{TX} lines. The analog signal processing is a
|
|
simple voltage divider using high-power resistors to get the required creepage along with some high-frequency filter
|
|
capacitors and an op-amp buffer. The power supply is an off-the-shelf mains-input power module. The system is
|
|
implemented on a single two-layer PCB that is housed in an off-the-shelf industrial plastic case fitted with a printed
|
|
label and a few status lights on its front.
|
|
|
|
\subsection{Clock accuracy considerations}
|
|
|
|
Our measurement hardware will sample line voltage at some sampling rate $f_S$, e.g.\ $1 \text{kHz}$. All downstream
|
|
processsing is limited in accuracy by the accuracy of $f_S$\footnote{
|
|
We are not considering the effects of clock jitter. We are highly oversampling the signal and the FFT done in our
|
|
downstream processing will eliminate small jitter effects leaving only frequency stability to worry about. }. We
|
|
generate our sampling clock in hardware by clocking the ADC from one of the microcontroller's timer blocks clocked from
|
|
the microcontroller's system clock. This means our ADC's sampling window will be synchronized cycle-accurate to the
|
|
microcontroller's system clock.
|
|
|
|
Our downstream measurement of mains frequency by nature is relative to our sampling frequency $f_S$. In the setup
|
|
described above this means we have to make sure our system clock is fairly stable. A frequency derivation of $1
|
|
\text{ppm}$ in our system clock causes a proportional grid frequency measurement error of $\Delta f = f_\text{nom} \cdot
|
|
10^{-6} = 50 \mu\text{Hz}$. In a worst-case where our system is clocked from a particularly bad crystal that exhibits
|
|
$100 \text{ppm}$ of instabilities over our measurement period we end up with an error of $5 \text{mHz}$. This is well
|
|
within our target measurement range, so we need a more stable clock source. Ideally we want to avoid writing our own
|
|
clock conditioning code where we try to change an oscillators operating frequency to match some reference. Clock
|
|
conditioning algorithms are highly complex and in our case post-processing of measurement data and simply adding and
|
|
offset is simpler and less error-prone.
|
|
|
|
Our solution to these problems is to use a crystal oven\footnote{
|
|
A crystal oven is a crystal oscillator thermally coupled closely to a heater and temperature sensor and enclosed in
|
|
a thermally isolated case. The heater is controlled to hold the crystal oscillator at a near-constant temperature
|
|
some few ten degrees above ambient. Any ambient temperature variations will be absorbed by the temperature control.
|
|
This yields a crystal frequency that is almost completely unaffected by ambient temperature variations below the
|
|
oven temperature and whose main remaining instability is aging.
|
|
}as our main system clock source. Crystal ovens are expensive compared to ordinary crystal oscillators. Since any
|
|
crystal oven will be much more accurate than a standard room-temperature crystal we chose to reduce cost by using one
|
|
recycled from old telecommunications equipment.
|
|
|
|
To verify clock accuracy we routed an externally accessible SMA connector to a microcontroller pin that is routed to one
|
|
of the microcontroller's timer inputs. By connecting a GPS 1pps signal to this pin and measuring its period we can
|
|
calculate our system's Allan variance\footnote{
|
|
Allan variance is a measure of frequency stability between two clocks.
|
|
}, thereby measuring both clock stability and clock accuracy.
|
|
We ran a 4 hour test of our frequency sensor that generated the histogram shown in figure \ref{ocxo_freq_stability}.
|
|
These results show that while we get a systematic error of about $10 \text{ppm}$ due to manufacturing tolerances the
|
|
random error at less than $10 \text{ppb}$ is smaller than that of a room-temperature crystal oscillator by 3-4 orders of
|
|
magnitude. Since we are interested in grid frequency variations over time but not in the absolute value of grid
|
|
frequency the systematic error is of no consequence to us. The random error at $3.66 \text{ppb}$ corresponds to a
|
|
frequency measurement error of about $0.2 \mu\text{Hz}$, well below what we can achieve at reasonable sampling rates and
|
|
ADC resolution.
|
|
|
|
\begin{figure}
|
|
\centering
|
|
\includegraphics{../lab-windows/fig_out/ocxo_freq_stability}
|
|
\caption{OCXO Frequency derivation from nominal $19.440 \text{MHz}$ measured against GPS 1pps}
|
|
\label{ocxo_freq_stability}
|
|
\end{figure}
|
|
|
|
\subsection{Firmware implementation}
|
|
|
|
The firmware uses one of the microcontroller's timers clocked from an external crystal oscillator to produce an $1
|
|
\text{ms}$ tick that the internal ADC is triggered from for a sample rate of $1 \text{ksps}$. Higher sample rates would
|
|
be possible but reliable data transmission over the opto-isolated serial interface might prove challenging and $1
|
|
\text{ksps}$ corresponds to $20$ samples per cycle at $f_\text{nominal}$. This is $10\times$ nyquist and should be
|
|
plenty for accurate measurements.
|
|
|
|
The ADC measurements are read using DMA and written into a circular buffer. Using some DMA controller features this
|
|
circular buffer is split in back and front halves with one being written to and the other being read at the same time.
|
|
Buffer contents are moved from the ADC DMA buffer into a packet-based reliable UART interface as they come in. The UART
|
|
packet interface keeps two ringbuffers: One byte-based ringbuffer for transmission data and one ringbuffer pointer
|
|
structure that keeps track of ADC data packet boundaries in the byte-based ringbuffer. Every time a chunk of data is
|
|
available from the ADC the data is framed into the byte-based ringbuffer and the packet boundaries are logged in the
|
|
packet pointer ringbuffer. If the UART transmitter is idle at this time a DMA-backed transmission of the oldest packet
|
|
in the packet ringbuffer is triggered at this point. Data is framed using Consistent Overhead Byte Stuffing
|
|
(COBS)\footnote{
|
|
COBS is a framing technique that allows encoding $n$ bytes of arbitray data into exactly $n+1$ bytes with no embedded
|
|
$0$-bytes that can then be delimited using $0$-bytes. COBS is simple to implement and allows both one-pass decoding and
|
|
encoding. The encoder either needs to be able to read up to $256 \text{bytes}$ ahead or needs a buffer of $256
|
|
\text{bytes}$. COBS is very robust in that it allows self-synchronization. At any point a receiver can reliably
|
|
synchronize itself against a COBS data stream by waiting for the next $0$-byte. The constant overhead allows precise
|
|
bandwidth and buffer planning and provides constant, good efficiency close to the theoretical maximum.
|
|
}\cite{cheshire01} along with a CRC-32 checksum for error checking. When the host receives a new packet with a
|
|
valid checksum it returns an acknowledgement packet to the sensor. When the sensor receives the acknowledgement, the
|
|
acknowledged packet is dropped from the transmission packet ringbuffer. When the host detects an incorrect checksum it
|
|
simply stays quiet and waits for the sensor to resume with retransmission when the next ADC buffer has been received.
|
|
|
|
% FIXME make actual error rate measurements
|
|
|
|
The serial interface logic presents most of the complexity of the sensor firmware. This complexity is necessary since
|
|
we need reliable, error-checked transmission to the host. Though rare, bit errors on a serial interface do happen and
|
|
data corruption is unacceptable. The packet-layer queueing on the sensor is necessary since the host is not a realtime
|
|
system and unpredictable latency spikes of several hundred milliseconds are possible.
|
|
|
|
The host in our recording setup is a Raspberry Pi 3 model B running a Python script. The Python script handles serial
|
|
communication and logs data and errors into an SQLite database file. SQLite has been chosen for its simple yet flexible
|
|
interface and its good tolerance of system resets due to unexpected power loss.
|
|
|
|
\subsection{Frequency sensor measurement results}
|
|
|
|
Captured raw waveform data is processed in the Jupyter Lab environment\cite{kluyver01} and grid frequency estimates are
|
|
extracted as described in sec. \ref{frequency_estimation} using the \textcite{gasior01} technique. Appendix
|
|
\ref{grid_freq_est_notebook} contains the Jupyter notebook we used for frequency measurement.
|
|
|
|
% FIXME comparison against reference measurements?
|
|
|
|
\section{Channel simulation and parameter validation}
|
|
|
|
|
|
\section{Implementation of a demonstrator unit}
|
|
|
|
\section{Experimental results}
|
|
|
|
\section{Lessons learned}
|
|
|
|
\chapter{Future work}
|
|
\section{Technical standardization}
|
|
The description of a safety reset system provided in this work could be translated into a formalized technical standard
|
|
with relatively low effort. Our system is very simple compared to e.g. a full smart meter communication standard and
|
|
thus can conceivably be described in a single, concise document. The much more complicated side of standardization would
|
|
be the standardization of the backend operation including key management, coordination and command authorization.
|
|
|
|
\section{Regulatory adoption}
|
|
Since the proposed system adds significant cost and development overhead at no immediate benefit to either consumer or
|
|
utility company it is unlikely that it would be adopted voluntarily. Market forces limit what long-term planning utility
|
|
companies can do. An advanced mitigation such as this one might be out of their reach on their own and might require
|
|
regulatory intervention to be implemented. To regulatory authorities a system such as this one provides a powerful
|
|
primitive to guard against attacks. Due to the low-level approach our system might allow a regulatory authority to
|
|
restore meters to a safe state without the need of fine-grained control of implementation details such as application
|
|
network protocols.
|
|
|
|
A regulatory authority might specify that all smart meters must use a standardized reset controller that on command
|
|
resets to a minimal firmware image that disables external communication, continues basic billing functions and enables
|
|
any disconnect switches. This system would enable the \emph{reset authority} to directly preempt a large-scale attack
|
|
irrespective of implementation details of the various smart meter implementations.
|
|
|
|
Cryptographic key management for the smart reset system is not much different to the management of highly privileged
|
|
signing keys as they are used in many other systems already. If the safety reset system is implemented with a
|
|
regulatory authority as the \emph{reset authority} they would likely be able to find a public entity that is already
|
|
managing root keys for other government systems to also manage safety reset keys. Availability and security requirements
|
|
of safety reset keys do not differ significantly from those for other types of root keys.
|
|
|
|
\section{Practical implementation}
|
|
|
|
|
|
\section{Zones of trust}
|
|
In our design, we opted for a safety reset controller
|
|
% FIXME is "safety reset" the proper name here? We need some sort of branding, but is this here really about "safety"?
|
|
in form of a separate micocontroller entirely separate from whatever application microcontroller the smart meter design
|
|
is already using. This design nicely separates the meter into an untrusted application (the core microcontroller) and
|
|
the trusted reset controller. Since the interface between the two is simple and logically one-way, it can be validated
|
|
to a high standard of security.
|
|
|
|
Despite these security benefits, the cost of such a separate hardware device might prove high in a mass-market rollout.
|
|
In this case, one might attempt to integrate the reset controller into the core microcontroller in some way. Primarily,
|
|
there would be two ways to accomplish this. One is a solution that physically integrates an additional microcontroller
|
|
core into the main application microcontroller package either as a submodule on the same die or as a separate die in a
|
|
multi-chip module (MCM) with the main application microcontroller. A full-custom solution integrating both on a single
|
|
die might be a viable path for very large-scale deployments, but will most likely be too expensive in tooling costs
|
|
alone to justify its use. More likely for a medium- to large-scale deployment (millions of meters) would be a MCM
|
|
integrating an off-the-shelf smart metering microcontroller die with the reset controller running on another, much
|
|
smaller off-the-shelf microcontroller die. This solution might potentially save some cost compared to a solution using a
|
|
discrete microcontroller for the reset controller.
|
|
|
|
The more likely approach to reducing cost overhead of the reset controller would be to employ virtualization
|
|
technologies such as ARM's TrustZone in order to incorporate the reset controller firmware into the application firmware
|
|
on the same chip without compromising the reset controller's security or disturbing the application firmware's
|
|
operation.
|
|
|
|
TrustZone is a virtualization technology that provides a hardware-assisted privileged execution domain on at least one
|
|
of the microcontrollers cores. In traditional virtualization setups a privileged hypervisor is managing several
|
|
unprivileged applications sharing resources between them. Separation between applications in this setup is longitudinal
|
|
between adjacent virtual machines. Two applications would both be running in unprivileged mode sharing the same cpu and
|
|
the hypervisor would merely schedule them, configure hardware resource access and coordinate communication. This
|
|
longitudinal virtualization simplifies application development since from the application's perspective the virtual
|
|
machine looks very similar to a physical one. In addition, in general this setup reciprocally isolates two applications
|
|
with neither one being able to gain control over the other.
|
|
|
|
In contrast to this, a TrustZone-like system in general does not provide several application virtual machines and
|
|
longitudinal separation. Instead, it provides lateral separation between two domains: The unprivileged application
|
|
firmware and a privileged hypervisor. Application firmware may communicate with the hypervisor through defined
|
|
interfaces but due to TrustZone's design it need not even be aware of the hypervisor's existence. This makes a perfect
|
|
fit for our reset controller. The reset controller firmware would be running in privileged mode and without exposing any
|
|
communication interfaces to application firmware. The application firmware would be running in unprivileged mode
|
|
without any modification. The main hurdles to the implementation to a system like this are the requirement for a
|
|
microcontroller providing this type of virtualization on the one hand and the complexity of correctly employing this
|
|
virtualization on the other hand. Virtualization systems such as TrustZone are still orders of magnitude more complex to
|
|
correctly configure than it is to simply use separate hardware and secure the interfaces in between.
|
|
|
|
\chapter{Conclusion}
|
|
|
|
\newpage
|
|
\appendix
|
|
\chapter{Acknowledgements}
|
|
\newpage
|
|
|
|
\chapter{References}
|
|
\nocite{*}
|
|
\printbibliography
|
|
\newpage
|
|
|
|
\chapter{Transcripts of Jupyter notebooks used in this thesis}
|
|
|
|
\section{Grid frequency estimation}
|
|
\label{grid_freq_est_notebook}
|
|
\fancyhead[C]{Included Jupyter notebook: Grid frequency estimation}
|
|
\includepdf[pages=-, pagecommand=\thispagestyle{fancy}]{resources/grid_freq_estimation.pdf}
|
|
|
|
\chapter{Demonstrator schematics and code}
|
|
|
|
\chapter{Economic viability of countermeasures}
|
|
\section{Attack cost}
|
|
\section{Countermeasure cost}
|
|
|
|
% FIXME maybe include a standard for the technical side of a safety reset system here, e.g. in the style of an IETF draft?
|
|
|
|