44 lines
1.5 KiB
YAML
44 lines
1.5 KiB
YAML
StaticCurrent:
|
|
Equation: Static Current Conduction
|
|
Variable: PotentialStat
|
|
Variable DOFs: 1
|
|
Procedure: '"StatCurrentSolve" "StatCurrentSolver"'
|
|
Calculate Volume Current: True
|
|
Calculate Joule Heating: False
|
|
Optimize Bandwidth: True
|
|
Nonlinear System Max Iterations: 1
|
|
Linear System Solver: Iterative
|
|
Linear System Iterative Method: CG
|
|
Linear System Max Iterations: 10000
|
|
Linear System Convergence Tolerance: 1e-10
|
|
Linear System Preconditioning: ILU3
|
|
Linear System ILUT Tolerance: 0.001
|
|
Linear System Abort Not Converged: False
|
|
Linear System Residual Output: 20
|
|
Linear System Precondition Recompute: 1
|
|
|
|
Electrostatics:
|
|
Equation: Electrostatics
|
|
Procedure: '"StatElecSolve" "StatElecSolver"'
|
|
Variable: Potential
|
|
Variable DOFs: 1
|
|
Calculate Electric Field: True
|
|
Calculate Electric Flux: True
|
|
Calculate Electric Energy: True
|
|
Steady State Convergence Tolerance: 1e-05
|
|
Nonlinear System Convergence Tolerance: 1e-07
|
|
Nonlinear System Max Iterations: 20
|
|
Nonlinear System Newton After Iterations: 3
|
|
Nonlinear System Newton After Tolerance: 0.001
|
|
Nonlinear System Relaxation Factor: 1
|
|
Linear System Solver: Iterative
|
|
Linear System Iterative Method: BiCGStab
|
|
Linear System Max Iterations: 5000
|
|
Linear System Convergence Tolerance: 1e-10
|
|
BiCGstabl polynomial degree: 2
|
|
Linear System Preconditioning: none
|
|
Linear System ILUT Tolerance: 0.001
|
|
Linear System Abort Not Converged: False
|
|
Linear System Residual Output: 10
|
|
Potential Difference: 1.0
|
|
|